{"id":11054,"date":"2026-09-23T11:35:24","date_gmt":"2026-09-23T03:35:24","guid":{"rendered":"https:\/\/oxy-boss.com\/?p=11054"},"modified":"2026-09-23T11:35:25","modified_gmt":"2026-09-23T03:35:25","slug":"atrasos-no-arranque-de-camaras-hiperbaricas-o-que-reunir-primeiro","status":"publish","type":"post","link":"https:\/\/oxy-boss.com\/pt\/hyperbaric-chamber-startup-delays-what-to-gather-first\/","title":{"rendered":"Atrasos no arranque de uma c\u00e2mara hiperb\u00e1rica: informa\u00e7\u00f5es a reunir antes de contactar a assist\u00eancia"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Engineer-reviewing-hyperbaric-chamber-equipment-information.webp\" alt=\"Engenheiro a analisar informa\u00e7\u00f5es t\u00e9cnicas de uma c\u00e2mara hiperb\u00e1rica\" class=\"wp-image-11055\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Engineer-reviewing-hyperbaric-chamber-equipment-information.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Engineer-reviewing-hyperbaric-chamber-equipment-information-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Engineer-reviewing-hyperbaric-chamber-equipment-information-768x480.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Para que serve esta p\u00e1gina.<\/strong>&nbsp;A sua c\u00e2mara n\u00e3o arranca, n\u00e3o insufla, demora a ganhar press\u00e3o ou n\u00e3o a mant\u00e9m, e vai contactar a assist\u00eancia. Esta p\u00e1gina indica o que verificar e anotar primeiro, para que a equipa t\u00e9cnica receba logo todas as informa\u00e7\u00f5es necess\u00e1rias.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>O que esta p\u00e1gina n\u00e3o \u00e9.<\/strong>&nbsp;N\u00e3o \u00e9 um plano para abrir um est\u00fadio de bem-estar, nem um guia para reconstruir a c\u00e2mara, nem aconselhamento m\u00e9dico. Se algu\u00e9m dentro se sentir mal, termine a sess\u00e3o, ajude a pessoa a sair e verifique como est\u00e1.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Os dois tempos que est\u00e1 realmente a medir<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Muitas queixas de que \u00aba minha c\u00e2mara \u00e9 lenta\u00bb esclarecem-se quando se pergunta qual \u00e9 o tempo medido. S\u00e3o dois, e respondem a quest\u00f5es diferentes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tempo 1 \u2014 tempo de pressuriza\u00e7\u00e3o recomendado.<\/strong>&nbsp;\u00c9 intencional: subir a press\u00e3o depressa demais pode causar dor nos ouvidos. O programa d\u00e1 tempo para equalizar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tempo 2 \u2014 tempo de enchimento mec\u00e2nico.<\/strong>&nbsp;A velocidade a que o compressor e a c\u00e2mara conseguem ganhar press\u00e3o com a porta fechada e sem fugas. \u00c9 uma caracter\u00edstica do equipamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se disser apenas \u00aba minha c\u00e2mara \u00e9 lenta\u00bb sem indicar qual dos tempos, ningu\u00e9m poder\u00e1 ajudar. Anote ambos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tempos de refer\u00eancia das nossas c\u00e2maras (enchimento mec\u00e2nico, c\u00e2mara vazia, ambiente ao n\u00edvel do mar):<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Press\u00e3o-alvo<\/th><th class=\"has-text-align-right\" data-align=\"right\">Tempo t\u00edpico<\/th><\/tr><\/thead><tbody><tr><td>1.3 ATA<\/td><td class=\"has-text-align-right\" data-align=\"right\">~5 min<\/td><\/tr><tr><td>1,5 ATA (c\u00e2maras flex\u00edveis, m\u00e1ximo)<\/td><td class=\"has-text-align-right\" data-align=\"right\">10\u201312 min<\/td><\/tr><tr><td>2,0 ATA (c\u00e2maras r\u00edgidas, m\u00e1ximo)<\/td><td class=\"has-text-align-right\" data-align=\"right\">20\u201325 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Os modelos maiores demoram um pouco mais. Se o tempo estiver a poucos minutos destes valores, est\u00e1 dentro do previsto, mesmo que antes parecesse mais r\u00e1pido. Se ultrapassar em dez minutos, h\u00e1 algo a verificar e esta p\u00e1gina \u00e9 para si.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Que tipo de c\u00e2mara utiliza?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O arranque varia conforme o tipo de c\u00e2mara. Identifique a sua antes de procurar a avaria.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/oxy-boss.com\/pt\/camara-hiperbarica-mole-portatil\/\">C\u00e2maras flex\u00edveis<\/a> (<a href=\"https:\/\/oxy-boss.com\/pt\/ot-s15t-camara-hiperbarica-de-oxigenio\/\">OT-S15T<\/a>, <a href=\"https:\/\/oxy-boss.com\/pt\/ot-s158-ot-s159-camara-hiperbarica\/\">OT-S158, OT-S159<\/a>)<\/strong>\u00a0\u2014 TPU de qualidade m\u00e9dica, m\u00e1ximo 1,5 ATA, ajust\u00e1vel a partir de 1,1 ATA. Compressor de ar e concentrador de oxig\u00e9nio de 10 L. O oxig\u00e9nio chega pela m\u00e1scara, n\u00e3o enche toda a c\u00e2mara.<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/oxy-boss.com\/pt\/capsula-hiperbarica-de-oxigenio\/\">C\u00e2maras r\u00edgidas tipo c\u00e1psula<\/a> (<a href=\"https:\/\/oxy-boss.com\/pt\/ot-h201-camara-hiperbarica\/\">OT-H201S, OT-H201M<\/a>)<\/strong>\u00a0\u2014 liga de alum\u00ednio, 1,1\u20132,0 ATA. Unidade 3 em 1 (concentrador de 10 L + compressor de ar + ar condicionado).<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/oxy-boss.com\/pt\/camara-hiperbarica-sentada-e-reclinavel\/\">C\u00e2maras r\u00edgidas para sentar<\/a> (<a href=\"https:\/\/oxy-boss.com\/pt\/ot-h202-camara-hiperbarica\/\">OT-H202<\/a>, OT-H301, OT-H401, OT-H402, OT-D201)<\/strong>\u00a0\u2014 liga de alum\u00ednio ou a\u00e7o-carbono Q235, 1,1\u20132,0 ATA. Mesma arquitetura 3 em 1; os modelos para duas pessoas fornecem 20 L de oxig\u00e9nio.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Em todos os modelos, a c\u00e2mara \u00e9 pressurizada com&nbsp;<strong>ar<\/strong>, n\u00e3o com oxig\u00e9nio. O oxig\u00e9nio a 90% \u00b1 3% chega ao utilizador por m\u00e1scara ou c\u00e2nula nasal. Esta distin\u00e7\u00e3o importa ao decidir o que pode entrar na c\u00e2mara.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Quatro sintomas e as suas poss\u00edveis causas<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. A c\u00e2mara n\u00e3o liga<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Quase sempre \u00e9 um problema de alimenta\u00e7\u00e3o na tomada, n\u00e3o da c\u00e2mara.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O disjuntor disparou? Rearme-o uma vez. Se disparar outra vez, pare: n\u00e3o o rearme pela terceira vez.<\/li>\n\n\n\n<li>A tomada n\u00e3o funciona? Teste com outro aparelho.<\/li>\n\n\n\n<li>O cabo de alimenta\u00e7\u00e3o est\u00e1 bem ligado nas duas extremidades?<\/li>\n\n\n\n<li>O ecr\u00e3 t\u00e1til fica escuro ou acende por instantes e depois apaga-se? S\u00e3o problemas diferentes. Anote qual acontece.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Se nada disto resolver, \u00e9 necess\u00e1rio o servi\u00e7o t\u00e9cnico. Passe \u00e0 ficha de informa\u00e7\u00f5es no fim.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. A c\u00e2mara liga, mas n\u00e3o insufla<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 quase sempre um problema mec\u00e2nico, normalmente na veda\u00e7\u00e3o.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Os fechos est\u00e3o fechados?<\/strong>\u00a0As c\u00e2maras flex\u00edveis t\u00eam uma ordem espec\u00edfica para fechar as camadas de fechos. Siga o manual e feche cada um at\u00e9 ao fim.<\/li>\n\n\n\n<li><strong>A porta est\u00e1 bem trancada?<\/strong>\u00a0Nas c\u00e2maras r\u00edgidas, veja o indicador do fecho: s\u00f3 tem dois estados.<\/li>\n\n\n\n<li><strong>Todas as v\u00e1lvulas de descarga est\u00e3o fechadas?<\/strong>\u00a0Verifique a v\u00e1lvula manual de descarga no interior e a do exterior. Se alguma estiver minimamente aberta, a press\u00e3o n\u00e3o sobe.<\/li>\n\n\n\n<li><strong>A mangueira de ar fresco est\u00e1 dobrada ou esmagada?<\/strong>\u00a0Verifique toda a extens\u00e3o entre a unidade 3 em 1 e a c\u00e2mara, sobretudo nas passagens pelo ch\u00e3o e atr\u00e1s da unidade.<\/li>\n\n\n\n<li><strong>A entrada de ar fresco est\u00e1 bloqueada?<\/strong>\u00a0A entrada de ar precisa de espa\u00e7o livre. Se a unidade estiver encostada \u00e0 parede ou bloqueada por um m\u00f3vel, afaste-a.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Regra pr\u00e1tica:&nbsp;<strong>se a c\u00e2mara n\u00e3o insuflar, procure primeiro entre a sa\u00edda do compressor e o interior da c\u00e2mara, n\u00e3o dentro do compressor<\/strong>, pelo menos numa primeira fase.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. A c\u00e2mara insufla, mas demora a atingir a press\u00e3o-alvo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Volte a verificar os dois tempos. A 1,5 ATA, demorar 14 minutos em vez de 10\u201312 pode estar dentro da varia\u00e7\u00e3o normal num dia quente, com a c\u00e2mara ocupada ou com o filtro de entrada a precisar de manuten\u00e7\u00e3o.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>O filtro de entrada precisa de manuten\u00e7\u00e3o?<\/strong>\u00a0Os filtros seguem um intervalo de 3\u20136 meses ou cerca de 500 horas de funcionamento. Um filtro sujo \u00e9 a causa mais comum de enchimento lento.<\/li>\n\n\n\n<li><strong>A temperatura ambiente est\u00e1 alta?<\/strong>\u00a0O compressor trabalha mais numa sala quente. O m\u00f3dulo de ar condicionado da unidade 3 em 1 regula a temperatura da c\u00e2mara, n\u00e3o a da sala do equipamento.<\/li>\n\n\n\n<li><strong>H\u00e1 uma pequena fuga numa liga\u00e7\u00e3o ou mangueira?<\/strong>\u00a0Pode ser pequena demais para se ouvir, mas suficiente para atrasar o enchimento. \u00c1gua com sab\u00e3o nas liga\u00e7\u00f5es ir\u00e1 revel\u00e1-la.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Se o enchimento demorar mais 50% ou mais do que a refer\u00eancia, comece por procurar uma fuga ou problema no filtro.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. A c\u00e2mara atinge a press\u00e3o, mas n\u00e3o a mant\u00e9m<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Um valor concreto ajuda muito no diagn\u00f3stico: quanta press\u00e3o se perde por minuto depois de o compressor desligar.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Leve a c\u00e2mara \u00e0 press\u00e3o-alvo.<\/li>\n\n\n\n<li>Anote a leitura do man\u00f3metro.<\/li>\n\n\n\n<li>Deixe-a assim durante 5 minutos sem tocar em nada.<\/li>\n\n\n\n<li>Anote novamente a leitura.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Anote os dois valores e o tempo entre eles. Assim a assist\u00eancia distingue desvio do sensor de uma fuga real.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se a press\u00e3o cair depressa o suficiente para ver no man\u00f3metro, n\u00e3o entre na c\u00e2mara: fa\u00e7a as verifica\u00e7\u00f5es com a c\u00e2mara vazia.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Checking-hyperbaric-chamber-door-seal-and-latch.webp\" alt=\"Checking hyperbaric chamber door seal and latch\" class=\"wp-image-11056\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Checking-hyperbaric-chamber-door-seal-and-latch.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Checking-hyperbaric-chamber-door-seal-and-latch-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Checking-hyperbaric-chamber-door-seal-and-latch-768x480.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Cinco verifica\u00e7\u00f5es que pode fazer e o que deixar para a assist\u00eancia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Fa\u00e7a isto:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Verifique tomada, cabo, disjuntor e interruptor.<\/li>\n\n\n\n<li>Confirme que todos os fechos, portas e v\u00e1lvulas de descarga est\u00e3o fechados.<\/li>\n\n\n\n<li>Verifique todas as mangueiras e liga\u00e7\u00f5es vis\u00edveis: dobras, esmagamentos ou pe\u00e7as soltas.<\/li>\n\n\n\n<li>Limpe a grelha de entrada, veja o filtro e confirme que nada bloqueia o ar \u00e0 volta da unidade.<\/li>\n\n\n\n<li>Anote as leituras do man\u00f3metro em repouso, durante a subida, na press\u00e3o-alvo e 5 minutos depois.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>N\u00e3o fa\u00e7a isto:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>N\u00e3o abra a caixa da unidade 3 em 1. Cont\u00e9m ar comprimido, concentrador de oxig\u00e9nio e eletr\u00f3nica; pode magoar-se e perder a garantia.<\/li>\n\n\n\n<li>N\u00e3o corte, emende nem substitua a mangueira de ar fresco por outra qualquer. Ela foi dimensionada para a press\u00e3o de servi\u00e7o.<\/li>\n\n\n\n<li>N\u00e3o force um fecho preso. Volte ao in\u00edcio e feche-o novamente.<\/li>\n\n\n\n<li>N\u00e3o altere a calibra\u00e7\u00e3o do sensor de press\u00e3o nem do analisador de oxig\u00e9nio.<\/li>\n\n\n\n<li>N\u00e3o use a c\u00e2mara se a janela acr\u00edlica tiver fissuras, microfissuras, esbranqui\u00e7amento ou danos vis\u00edveis nas bordas. Termine a sess\u00e3o e contacte a assist\u00eancia.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Quando terminar imediatamente a sess\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Alguns sinais permitem ligar \u00e0 assist\u00eancia mais tarde. Estes exigem terminar a sess\u00e3o agora, abrir a porta s\u00f3 quando a press\u00e3o voltar \u00e0 ambiente e n\u00e3o usar a c\u00e2mara at\u00e9 ser verificada:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cheiro a queimado ou pl\u00e1stico, ou fumo vis\u00edvel na unidade ou dentro da c\u00e2mara.<\/li>\n\n\n\n<li>Disparos repetidos do disjuntor diferencial ou do disjuntor na mesma sess\u00e3o.<\/li>\n\n\n\n<li>Ru\u00eddo met\u00e1lico forte de raspagem ou pancadas vindo do compressor.<\/li>\n\n\n\n<li>Fissura vis\u00edvel, esbranqui\u00e7amento ou dano na borda da janela acr\u00edlica.<\/li>\n\n\n\n<li>Qualquer deforma\u00e7\u00e3o do corpo ou da porta da c\u00e2mara.<\/li>\n\n\n\n<li>Alarme de oxig\u00e9nio ambiente da c\u00e2mara a 24% (o ar interior n\u00e3o deve ultrapassar ~21%; 24% indica uma fuga importante na m\u00e1scara ou um tubo de exaust\u00e3o solto).<\/li>\n\n\n\n<li>Man\u00f3metro acima de 2,0 ATA numa c\u00e2mara r\u00edgida ou 1,5 ATA numa flex\u00edvel, e a press\u00e3o continua a subir.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A c\u00e2mara tem uma v\u00e1lvula autom\u00e1tica de al\u00edvio e uma v\u00e1lvula mec\u00e2nica manual de descarga, uma dentro e outra fora, que funcionam sem eletricidade. Foram concebidas para esta situa\u00e7\u00e3o. Quando a press\u00e3o volta \u00e0 ambiente, a porta abre \u00e0 m\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para riscos associados a c\u00e2maras hiperb\u00e1ricas, a FDA dos EUA publicou um aviso de seguran\u00e7a sobre sinais de alerta e como comunicar incidentes. Guarde-o com o manual do fabricante (ver a&nbsp;<a href=\"https:\/\/www.fda.gov\/medical-devices\/safety-communications\" target=\"_blank\" rel=\"noopener\">aviso de seguran\u00e7a da FDA sobre c\u00e2maras hiperb\u00e1ricas fora do hospital<\/a>).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">O que pode levar para dentro da c\u00e2mara e o que deve ficar de fora<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 aqui que costuma haver confus\u00e3o, porque na internet se misturam dois tipos diferentes de c\u00e2mara.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>As nossas c\u00e2maras s\u00e3o pressurizadas com ar.<\/strong>&nbsp;O oxig\u00e9nio a 90% chega ao utilizador apenas pela m\u00e1scara ou c\u00e2nula nasal. Por isso, a regra rigorosa de \u00absem materiais sint\u00e9ticos, produtos \u00e0 base de petr\u00f3leo ou equipamentos eletr\u00f3nicos\u00bb, aplic\u00e1vel a c\u00e2maras pressurizadas totalmente com oxig\u00e9nio, n\u00e3o conta a hist\u00f3ria toda aqui. O que importa \u00e9 a&nbsp;<strong>zona de contacto com o oxig\u00e9nio<\/strong>&nbsp;\u2014 a m\u00e1scara, o tubo, as liga\u00e7\u00f5es e tudo o que estiver ao alcance de um bra\u00e7o deles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mantenha fora da zona de contacto com o oxig\u00e9nio:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Produtos para a pele \u00e0 base de petr\u00f3leo (vaselina, cremes oleosos, b\u00e1lsamo labial) no rosto ou nas m\u00e3os. Refer\u00eancia:\u00a0<a href=\"https:\/\/www.cganet.com\/\" target=\"_blank\" rel=\"noopener\">Compressed Gas Association CGA G-4.1<\/a>\u00a0sobre a limpeza de equipamentos para servi\u00e7o com oxig\u00e9nio.<\/li>\n\n\n\n<li>Roupa sint\u00e9tica que produza eletricidade est\u00e1tica perto da m\u00e1scara.<\/li>\n\n\n\n<li>Aeross\u00f3is e desinfetante das m\u00e3os \u00e0 base de \u00e1lcool aplicado mesmo antes de entrar.<\/li>\n\n\n\n<li>Qualquer objeto aceso. Sem exce\u00e7\u00f5es.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Permitido dentro da c\u00e2mara (mas n\u00e3o dentro da m\u00e1scara):<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Roupa de algod\u00e3o. De prefer\u00eancia larga.<\/li>\n\n\n\n<li>Dispositivos de baixa tens\u00e3o abaixo de 24 V: telem\u00f3veis, tablets e leitores digitais. Os carregadores ficam de fora.<\/li>\n\n\n\n<li>Um livro, uma garrafa de \u00e1gua, uma almofada.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Nunca dentro da c\u00e2mara, seja qual for o modelo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Isqueiros, f\u00f3sforos, cigarros eletr\u00f3nicos e vapes.<\/li>\n\n\n\n<li>Aquecedores port\u00e1teis, secadores de cabelo e qualquer aparelho com um elemento de aquecimento exposto.<\/li>\n\n\n\n<li>Qualquer dispositivo com uma bateria de l\u00edtio danificada, inchada ou com v\u00e1rios anos.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Se as sess\u00f5es comerciais forem seguidas, limpe e enxague a m\u00e1scara entre utilizadores. N\u00e3o partilhe m\u00e1scaras sem as limpar. As m\u00e1scaras de substitui\u00e7\u00e3o s\u00e3o baratas e vale a pena t\u00ea-las.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Remote-support-discussion-beside-a-hyperbaric-chamber.webp\" alt=\"Remote support discussion beside a hyperbaric chamber\" class=\"wp-image-11057\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Remote-support-discussion-beside-a-hyperbaric-chamber.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Remote-support-discussion-beside-a-hyperbaric-chamber-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Remote-support-discussion-beside-a-hyperbaric-chamber-768x480.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Ficha de informa\u00e7\u00f5es: o que reunir antes de nos contactar<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Esta ficha \u00e9 o centro da p\u00e1gina. Preencha-a uma vez e cole-a na sua mensagem. Pode reduzir o tempo de resposta de dias para horas e ajuda-nos a decidir entre \u00abenviamos uma pe\u00e7a\u00bb e \u00abfazemos uma videochamada para perceber o problema\u00bb.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Identifica\u00e7\u00e3o da unidade<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Modelo (OB-S15T \/ OB-H201S \/ OB-H301 \/ etc.)<\/li>\n\n\n\n<li>N\u00famero de s\u00e9rie (na placa de identifica\u00e7\u00e3o \u2014 tire uma fotografia \u00e0 placa inteira)<\/li>\n\n\n\n<li>Data aproximada de compra ou entrega<\/li>\n\n\n\n<li>Estado da garantia, se souber<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">O que est\u00e1 a observar<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Qual dos quatro sintomas acima corresponde ao seu caso (n\u00e3o liga \/ n\u00e3o insufla \/ demora a atingir a press\u00e3o \/ n\u00e3o mant\u00e9m a press\u00e3o)<\/li>\n\n\n\n<li>Quando come\u00e7ou \u2014 nesta sess\u00e3o ou gradualmente nas \u00faltimas semanas<\/li>\n\n\n\n<li>Acontece sempre ou s\u00f3 de vez em quando?<\/li>\n\n\n\n<li>Acontece com a c\u00e2mara vazia e tamb\u00e9m ocupada?<\/li>\n\n\n\n<li>Mudou alguma coisa recentemente \u2014 deslocou ou limpou a unidade, houve uma falha de energia, instalou um filtro novo ou mudou o ambiente?<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Valores de que precisamos<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Press\u00e3o alvo que tentava atingir<\/li>\n\n\n\n<li>Press\u00e3o real atingida pela c\u00e2mara e tempo necess\u00e1rio<\/li>\n\n\n\n<li>Leitura do man\u00f3metro em repouso (c\u00e2mara despressurizada, unidade desligada)<\/li>\n\n\n\n<li>Leitura do man\u00f3metro na press\u00e3o alvo<\/li>\n\n\n\n<li>Leitura do man\u00f3metro 5 minutos depois de atingir a press\u00e3o alvo, com a c\u00e2mara fechada e em repouso<\/li>\n\n\n\n<li>Temperatura ambiente da sala<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Fotografias e v\u00eddeos curtos<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A placa de identifica\u00e7\u00e3o completa, n\u00edtida e leg\u00edvel<\/li>\n\n\n\n<li>O man\u00f3metro \u00e0 press\u00e3o alvo<\/li>\n\n\n\n<li>Qualquer c\u00f3digo de alarme, luz de aviso ou mensagem de erro no ecr\u00e3 t\u00e1til (fotografe o ecr\u00e3, n\u00e3o transcreva)<\/li>\n\n\n\n<li>A entrada de ar da c\u00e2mara e a zona imediatamente \u00e0 volta<\/li>\n\n\n\n<li>Um v\u00eddeo de 20 a 30 segundos do arranque completo: ecr\u00e3 ligado, v\u00e1lvulas a fechar, in\u00edcio da subida de press\u00e3o e man\u00f3metro a subir<\/li>\n\n\n\n<li>Se suspeitar de uma fuga, um grande plano do local por onde acha que o ar est\u00e1 a sair<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hist\u00f3rico recente<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Data da \u00faltima sess\u00e3o conclu\u00edda sem problemas<\/li>\n\n\n\n<li>Qualquer pe\u00e7a ou componente substitu\u00eddo nos \u00faltimos 12 meses<\/li>\n\n\n\n<li>Data da \u00faltima troca do filtro de admiss\u00e3o<\/li>\n\n\n\n<li>Data da \u00faltima inspe\u00e7\u00e3o da veda\u00e7\u00e3o da porta (recomendada anualmente)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Como funciona realmente a assist\u00eancia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Muitos guias d\u00e3o a ideia de que um t\u00e9cnico vai a sua casa com uma caixa de ferramentas e trabalha durante duas horas. N\u00e3o \u00e9 assim que o nosso servi\u00e7o funciona e, normalmente, n\u00e3o \u00e9 disso que precisa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>O processo \u00e9 este:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Envia-nos a ficha de informa\u00e7\u00f5es, as fotografias e o v\u00eddeo.<\/li>\n\n\n\n<li>No prazo de 48 horas, o nosso engenheiro confirma qual \u00e9 o m\u00f3dulo provavelmente envolvido.<\/li>\n\n\n\n<li>Se for necess\u00e1ria uma pe\u00e7a de substitui\u00e7\u00e3o, \u00e9 enviada no prazo de 3 a 5 dias (o tempo de transporte depende da sua localiza\u00e7\u00e3o).<\/li>\n\n\n\n<li>Faz a substitui\u00e7\u00e3o com o nosso engenheiro por videochamada. Gra\u00e7as \u00e0 arquitetura modular 3 em 1, na maioria dos casos basta desligar o m\u00f3dulo antigo e ligar o novo. Nunca use ferramentas dentro de uma c\u00e2mara pressurizada.<\/li>\n\n\n\n<li>Se for uma quest\u00e3o de configura\u00e7\u00e3o, calibra\u00e7\u00e3o ou procedimento de utiliza\u00e7\u00e3o, a videochamada resolve o problema sem envio de pe\u00e7as.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Isto significa duas coisas para si:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Preencher corretamente a ficha logo na primeira mensagem ajuda mais do que quaisquer tentativas de diagn\u00f3stico por conta pr\u00f3pria.<\/strong>\u00a0Uma fotografia n\u00edtida da placa de identifica\u00e7\u00e3o e do ecr\u00e3 de alarme \u00e9 mais \u00fatil do que um longo texto.<\/li>\n\n\n\n<li><strong>N\u00e3o fique \u00e0 espera de uma visita ao local que n\u00e3o est\u00e1 prevista.<\/strong>\u00a0Para equipamentos de bem-estar n\u00e3o m\u00e9dicos, o envio de t\u00e9cnicos ao local em todo o mundo n\u00e3o \u00e9 o modelo habitual de assist\u00eancia, seja qual for o fornecedor. O diagn\u00f3stico remoto e a troca do m\u00f3dulo s\u00e3o mais r\u00e1pidos e econ\u00f3micos.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Documentos a ter \u00e0 m\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e3o porque algu\u00e9m v\u00e1 necessariamente pedir-lhos, mas porque, se a c\u00e2mara ficar parada alguns dias, permitem que outra pessoa continue a partir do ponto em que ficou.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O manual de utiliza\u00e7\u00e3o do\u00a0<strong>seu modelo espec\u00edfico<\/strong>. Os c\u00f3digos de alarme e os menus do ecr\u00e3 variam conforme o modelo.<\/li>\n\n\n\n<li>A fatura de compra ou confirma\u00e7\u00e3o da encomenda. \u00c9 o comprovativo da garantia.<\/li>\n\n\n\n<li>As fotografias da entrega (muita gente tira-as e depois esquece-se delas).<\/li>\n\n\n\n<li>Qualquer v\u00eddeo dos testes de aceita\u00e7\u00e3o em f\u00e1brica enviado pelo fabricante antes do envio: manuten\u00e7\u00e3o da press\u00e3o, verifica\u00e7\u00e3o da concentra\u00e7\u00e3o de oxig\u00e9nio e teste de fugas.<\/li>\n\n\n\n<li>Os certificados da sua unidade: para c\u00e2maras r\u00edgidas vendidas no EEE, o certificado CE\/PED (Diretiva 2014\/68\/UE, M\u00f3dulo H). Para o sistema de gest\u00e3o da qualidade, ISO 9001 e ISO 13485. Consulte a\u00a0<a href=\"https:\/\/single-market-economy.ec.europa.eu\/single-market\/european-standards\/harmonised-standards\/pressure-equipment_en\" target=\"_blank\" rel=\"noopener\">refer\u00eancia da Comiss\u00e3o Europeia \u00e0 PED<\/a>.<\/li>\n\n\n\n<li>O registo de instala\u00e7\u00f5es, desloca\u00e7\u00f5es, trocas de filtro e inspe\u00e7\u00f5es das veda\u00e7\u00f5es. Uma p\u00e1gina num caderno chega.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Um ritmo de manuten\u00e7\u00e3o razo\u00e1vel<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Esta n\u00e3o \u00e9 uma p\u00e1gina de manuten\u00e7\u00e3o, mas este ponto deve estar aqui: muitos atrasos de arranque \u00abrepentinos\u00bb resultam de um intervalo de manuten\u00e7\u00e3o esquecido.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Em cada sess\u00e3o:<\/strong>\u00a0Limpe o interior com um pano macio. Depois de despressurizar, deixe arejar durante 10 a 15 minutos.<\/li>\n\n\n\n<li><strong>A cada 3\u20136 meses ou cerca de 500 horas de funcionamento:<\/strong>\u00a0Inspecione e troque o filtro de admiss\u00e3o. Verifique o dreno.<\/li>\n\n\n\n<li><strong>A cada 12 meses:<\/strong>\u00a0Inspecione a veda\u00e7\u00e3o da porta e o sistema de al\u00edvio de press\u00e3o. Verifique as v\u00e1lvulas de emerg\u00eancia.<\/li>\n\n\n\n<li><strong>Segundo o calend\u00e1rio indicado no manual:<\/strong>\u00a0Verifique o sensor e o man\u00f3metro com uma refer\u00eancia.<\/li>\n\n\n\n<li><strong>Antes de cada utiliza\u00e7\u00e3o:<\/strong>\u00a0Procure fissuras ou microfissuras na janela de acr\u00edlico. Se encontrar alguma, n\u00e3o utilize a c\u00e2mara.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Substitua os consum\u00edveis conforme os respetivos intervalos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kit de filtro de ar: a cada 500\u20131 000 horas de funcionamento<\/li>\n\n\n\n<li>Veda\u00e7\u00e3o da porta: a cada 2 anos ou quando um teste de estanquidade detetar uma fuga<\/li>\n\n\n\n<li>Peneiro molecular: a cada 5 000\u20138 000 horas de funcionamento (lado do concentrador, n\u00e3o da c\u00e2mara)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Normas e refer\u00eancias que seguimos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para quem quiser consultar a documenta\u00e7\u00e3o:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>NFPA 99 \u2014 Health Care Facilities Code, Chapter 14<\/strong>\u00a0abrange instala\u00e7\u00f5es hiperb\u00e1ricas. Para operadores comerciais, serve de refer\u00eancia para o ambiente em torno do equipamento. Consulte\u00a0<a href=\"https:\/\/www.nfpa.org\/\" target=\"_blank\" rel=\"noopener\">a p\u00e1gina p\u00fablica de refer\u00eancia da NFPA<\/a>.<\/li>\n\n\n\n<li><strong>ASME PVHO-1<\/strong>\u00a0\u2014 recipientes sob press\u00e3o para ocupa\u00e7\u00e3o humana. Os recipientes sob press\u00e3o das nossas c\u00e2maras r\u00edgidas s\u00e3o concebidos segundo esta fam\u00edlia de normas; a norma est\u00e1 dispon\u00edvel atrav\u00e9s da\u00a0<a href=\"https:\/\/www.asme.org\/\" target=\"_blank\" rel=\"noopener\">ASME<\/a>.<\/li>\n\n\n\n<li><strong>Diretiva Europeia 2014\/68\/UE relativa a equipamentos sob press\u00e3o<\/strong>\u00a0\u2014 o enquadramento regulamentar da marca\u00e7\u00e3o CE\/PED das nossas c\u00e2maras r\u00edgidas.<\/li>\n\n\n\n<li><strong>Comunicado de seguran\u00e7a p\u00fablica da FDA<\/strong>\u00a0sobre c\u00e2maras hiperb\u00e1ricas fora dos hospitais \u2014 vale a pena l\u00ea-la antes da utiliza\u00e7\u00e3o comercial.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e3o afirmamos que os nossos produtos tenham autoriza\u00e7\u00e3o, aprova\u00e7\u00e3o ou registo da FDA como dispositivos m\u00e9dicos, porque s\u00e3o equipamentos de bem-estar, n\u00e3o dispositivos m\u00e9dicos. Esta distin\u00e7\u00e3o \u00e9 intencional e n\u00e3o altera aquilo para que o equipamento foi concebido dentro dos seus limites nominais.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Guia r\u00e1pido: sinais vermelhos e amarelos<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vermelho: interrompa a sess\u00e3o e n\u00e3o volte a ligar antes de uma inspe\u00e7\u00e3o:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cheiro a queimado, fumo ou disparos repetidos do disjuntor<\/li>\n\n\n\n<li>Janela com fissuras ou esbranqui\u00e7ada<\/li>\n\n\n\n<li>Ru\u00eddo met\u00e1lico forte vindo do compressor<\/li>\n\n\n\n<li>Alarme de oxig\u00e9nio no ar da c\u00e2mara acima de 23,5%<\/li>\n\n\n\n<li>Press\u00e3o descontrolada que continua a subir acima do m\u00e1ximo nominal<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Amarelo: termine normalmente a sess\u00e3o em curso e verifique antes da seguinte:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tempo de enchimento claramente superior aos valores de refer\u00eancia acima<\/li>\n\n\n\n<li>Novo ru\u00eddo ou altera\u00e7\u00e3o do som do compressor<\/li>\n\n\n\n<li>Pequena varia\u00e7\u00e3o de press\u00e3o durante o teste de reten\u00e7\u00e3o de 5 minutos<\/li>\n\n\n\n<li>Troca do filtro atrasada h\u00e1 mais de 30 dias<\/li>\n\n\n\n<li>Disparo \u00fanico do disjuntor diferencial GFCI, rearmado sem problemas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Verde: normal, n\u00e3o \u00e9 preciso fazer nada:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A c\u00e2mara n\u00e3o insufla de imediato: o enchimento demora 5 a 25 minutos, consoante a press\u00e3o alvo e a dimens\u00e3o do modelo<\/li>\n\n\n\n<li>Pequena diferen\u00e7a no tempo de enchimento entre uma manh\u00e3 fria e uma tarde quente<\/li>\n\n\n\n<li>A press\u00e3o estabiliza um pouco abaixo do valor anterior quando o compressor desliga, porque o ar arrefece ligeiramente<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Perguntas frequentes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Porque \u00e9 que a minha c\u00e2mara demora mais do que a de um amigo?<\/strong><br>O modelo, o tamanho, a press\u00e3o alvo e a temperatura ambiente podem ser diferentes. Compare com os tempos de refer\u00eancia do seu modelo, n\u00e3o com a sess\u00e3o de outra pessoa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A c\u00e2mara deve insuflar de imediato?<\/strong><br>N\u00e3o. A subida de press\u00e3o \u00e9 controlada para os ouvidos do utilizador; n\u00e3o \u00e9 uma corrida. Subir demasiado depressa \u00e9 uma falha de conce\u00e7\u00e3o, n\u00e3o uma vantagem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Posso usar a c\u00e2mara se o man\u00f3metro mostrar um valor ligeiramente diferente do da semana passada?<\/strong><br>Se a diferen\u00e7a for de poucos por cento e tudo o resto estiver normal, sim. Se houver um grande salto ou se a leitura mudar visivelmente enquanto observa, n\u00e3o: pode ser um problema no sensor ou uma fuga.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Preciso de um t\u00e9cnico certificado para repor alarmes?<\/strong><br>N\u00e3o, se o alarme estiver documentado no manual com um procedimento de reposi\u00e7\u00e3o para o operador. Se n\u00e3o constar do manual, exigir a abertura da caixa ou acontecer mais do que uma vez, ligue-nos primeiro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Posso mudar a c\u00e2mara sozinho para outra divis\u00e3o?<\/strong><br>As c\u00e2maras flex\u00edveis, sim: pesam 18\u201324 kg. As r\u00edgidas pesam 300\u2013900 kg e exigem equipamento adequado. Depois de qualquer desloca\u00e7\u00e3o, fa\u00e7a o teste de reten\u00e7\u00e3o de press\u00e3o de 5 minutos com a c\u00e2mara vazia antes da primeira sess\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>O que acontece se faltar a eletricidade a meio da sess\u00e3o?<\/strong><br>As v\u00e1lvulas mec\u00e2nicas de descarga manual, dentro e fora, funcionam sem eletricidade. Quando a press\u00e3o regressar \u00e0 press\u00e3o ambiente, a porta abre \u00e0 m\u00e3o. N\u00e3o force nada enquanto a c\u00e2mara estiver pressurizada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9 normal a m\u00e1scara embaciar?<\/strong><br>Um pouco, devido \u00e0 respira\u00e7\u00e3o. Se embaciar tanto que n\u00e3o consegue ver, est\u00e1 mal ajustada ou a sa\u00edda de ar est\u00e1 obstru\u00edda. Reajuste-a antes de concluir que est\u00e1 avariada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Como sei se \u00e9 o sensor ou uma fuga real?<\/strong><br>Fa\u00e7a o teste de reten\u00e7\u00e3o de 5 minutos com a c\u00e2mara vazia e fechada. Se a press\u00e3o cair sem ningu\u00e9m dentro nem ningu\u00e9m a mexer em nada, h\u00e1 uma fuga real. Se se mantiver mas a leitura parecer errada, o problema \u00e9 provavelmente do sensor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>E se comprei a c\u00e2mara usada a outro propriet\u00e1rio?<\/strong><br>Envie-nos o n\u00famero de s\u00e9rie. Podemos indicar a data de fabrico, a data da primeira entrega e a garantia que ainda esteja v\u00e1lida. O segundo propriet\u00e1rio tem acesso a assist\u00eancia ao pre\u00e7o das pe\u00e7as.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Numa frase<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Os problemas de arranque devem-se quase sempre a veda\u00e7\u00f5es, v\u00e1lvulas, filtros ou a uma fotografia de que a assist\u00eancia precisa. Preencha a ficha e envie-a com fotografias e um v\u00eddeo curto: assim evita a maioria das trocas de mensagens.<\/p>","protected":false},"excerpt":{"rendered":"<p>What this page is.&nbsp;Your chamber won&#8217;t start, won&#8217;t inflate, is slow to build pressure, or won&#8217;t hold pressure \u2014 and you&#8217;re about to reach out for support. This page tells you what to check first and what to write down, so the first message to your service team already has everything they need. What this [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":11055,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-11054","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/posts\/11054","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/comments?post=11054"}],"version-history":[{"count":1,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/posts\/11054\/revisions"}],"predecessor-version":[{"id":11058,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/posts\/11054\/revisions\/11058"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/media\/11055"}],"wp:attachment":[{"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/media?parent=11054"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/categories?post=11054"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oxy-boss.com\/pt\/wp-json\/wp\/v2\/tags?post=11054"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}