{"id":11640,"date":"2026-10-14T11:56:07","date_gmt":"2026-10-14T03:56:07","guid":{"rendered":"https:\/\/oxy-boss.com\/?p=11640"},"modified":"2026-10-14T11:56:09","modified_gmt":"2026-10-14T03:56:09","slug":"puscanje-hiperbaricna-komora-izguba-tlaka-hitror","status":"publish","type":"post","link":"https:\/\/oxy-boss.com\/sl\/hyperbaric-chamber-leak-detection-find-pressure-loss-fast\/","title":{"rendered":"Hiperbari\u010dna komora 101: poi\u0161\u010di pu\u0161\u010danje, preden ti po\u017ere seanso"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Minimalist-close-up-of-a-hyperbaric-chamber-door-seal.webp\" alt=\"Minimalisti\u010dni posnetek od blizu tesnila vrat hiperbari\u010dne komore\" class=\"wp-image-11641\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Minimalist-close-up-of-a-hyperbaric-chamber-door-seal.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Minimalist-close-up-of-a-hyperbaric-chamber-door-seal-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Minimalist-close-up-of-a-hyperbaric-chamber-door-seal-768x480.webp 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Minimalist-close-up-of-a-hyperbaric-chamber-door-seal-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Izdelujemo <a href=\"https:\/\/oxy-boss.com\/sl\/\">hiperbari\u010dne komore<\/a>. In tole povemo vsaki stranki, ki pokli\u010de zaradi po\u010dasnega dviga tlaka:\u00a0<strong>tvoja komora bo pu\u0161\u010dala<\/strong>. Ne \u00bb\u010de\u00ab, ampak \u00bbkdaj\u00ab. Tesnila vrat se obrabijo, usedi ventilov se razjedajo, akrilna okna dobijo mikrorazpoke. Vpra\u0161anje ni, ali se bo zgodilo \u2014 ampak ali bo\u0161 to ujel, preden ti po\u017ere \u010das seans, kisik in kapaciteto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tole ni zato, da bi ti kaj prodali. Tole je, koliko pu\u0161\u010danje v nastajanju v resnici stane, kje nastane in kako ga najde\u0161 z orodjem, ki ga verjetno \u017ee ima\u0161.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Koliko stane eno pu\u0161\u010danje (ra\u010dun, ki se mu nih\u010de no\u010de posvetiti)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Komora z 6 seansami na dan pri 1,5 ATA, vsaka po 60 minut. Tesnilo vrat za\u010dne popu\u0161\u010dati. Polnjenje s tlakom se podalj\u0161a za 8 minut na seanso. To je&nbsp;<strong>48 izgubljenih minut na dan<\/strong>\u2014skoraj cela seansa. Na mesec:&nbsp;<strong>24 ur kapacitete<\/strong>&nbsp;je \u0161lo v ni\u010d. \u010ce zara\u010duna\u0161 150 $ na seanso, te je to pu\u0161\u010danje stalo 3.600 $ izgubljenega prometa, plus kisik, ki ga pokuri\u0161 za dr\u017eanje tlaka proti njemu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kompresor ne ve, da se bori s pu\u0161\u010danjem. Preprosto te\u010de dlje. Tudi \u0161tevec elektrike ne ve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In stranke to opazijo. Ko se 60-minutna seansa razvle\u010de na 75 minut, se za\u010dnejo spra\u0161evati, ali to deluje. To ni ve\u010d tehni\u010dna te\u017eava \u2014 to je te\u017eava zaupanja.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kje nastanejo pu\u0161\u010danja<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Tesnila vrat in tesnilni obro\u010di<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Za vse krivijo tesnila vrat, ker so ponavadi res kriva. Elastomeri se v okolju, bogatem s kisikom, razgrajujejo. UV sevanje skozi okno jih \u0161e pospe\u0161i. Onesna\u017eenje z izdelki na osnovi nafte (ki v komoro ne bi smeli priti, pa pogosto pridejo) material otrdi. Tesnilo, ki se je pred 18 meseci \u0161e popolnoma stisnilo, zdaj pu\u0161\u010da 0,5 mm veliko \u0161pranjo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Intervali zamenjave so odvisni od tega, koliko komoro uporablja\u0161 in kako \u010dist je kisik, ampak \u010de jih ignorira\u0161, na koncu pla\u010da\u0161 ve\u010d kot tesnilo za 120\u2013180 $.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vretena ventilov in priklju\u010dki<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Medeninasti used na dovodnem ventilu se obrablja zaradi delcev v stisnjenem zraku. O-obro\u010d v hitri spojki se izsu\u0161i. Tako nastanejo pu\u0161\u010danja 2\u20135 psi\/min \u2014 premajhna, da bi jih sli\u0161al, dovolj velika, da se tvojih 12 minut polnjenja spremeni v 18 minut.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Toplotno varjena tkanina in okna<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kar zadeva <a href=\"https:\/\/oxy-boss.com\/sl\/mehka-prenosna-hiperbaricna-komora\/\">mehke komore<\/a>, akrilna okna, name\u0161\u010dena pod napetostjo, z leti razvijejo napetostne razpoke. \u0160ivi tkanine se razmaknejo za nekaj milimetrov po odseku, dolgem \u0161est palcev (15 cm). Tega ne bo\u0161 videl na oko. Videl bo\u0161, da osnovni \u010das polnjenja iz meseca v mesec raste.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Varnostni ventili<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ko varnostni ventil pu\u0161\u010da, so posledice resne. \u010ce komora ne dr\u017ei tlaka niti ob neprekinjeno delujo\u010dem kompresorju, ventil verjetno klepe\u010de ali je zataknjen na pol odprt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kar spregledamo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Preboji<\/strong>\u2014 povsod, kjer kabel, cev ali senzor prehaja skozi steno komore. Tesnilna masa se razgradi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>To\u010dke upogibanja okvirja<\/strong>&nbsp;pri mehkih komorah. Neravne povr\u0161ine ali pogosta premikanja ustvarijo lokalne obremenitve in s\u010dasoma popustijo \u0161ivi.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Soft-chamber-window-and-welded-seam.webp\" alt=\"Okno mehke komore in zvarjeni \u0161iv\" class=\"wp-image-11642\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Soft-chamber-window-and-welded-seam.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Soft-chamber-window-and-welded-seam-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Soft-chamber-window-and-welded-seam-768x480.webp 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Soft-chamber-window-and-welded-seam-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Kako jih najti (brez detektorja za helij za 15.000 $)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Najde\u0161 vodnike, ki priporo\u010dajo detektorje pu\u0161\u010danja s helijem, ultrazvo\u010dne sonde ali preizkus z akusti\u010dno emisijo. Za mehko komoro z 1,3\u20131,5 ATA je to pretirano in\u017eenirstvo, izposojeno iz podmornic in vesoljske tehnike. Tega ne potrebuje\u0161.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Preizkus zadr\u017eevanja tlaka<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Zapri prazno komoro, napolni jo na delovni tlak (1,5 ATA = ~7 psig), izklopi kompresor, zapri izolacijski ventil in&nbsp;<strong>opazuj merilnik tlaka 10\u201315 minut<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prakti\u010dne meje:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u22640,1 psi\/min<\/strong>\u00a0= dobro tesnjenje, ni\u010d ni treba ukrepati<\/li>\n\n\n\n<li><strong>0,1\u20130,3 psi\/min<\/strong>\u00a0= pu\u0161\u010danje v nastajanju, pregled v 30 dneh<\/li>\n\n\n\n<li><strong>&gt;0,3 psi\/min<\/strong>\u00a0= aktivno pu\u0161\u010danje, popravilo pred naslednjo seanso<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u010ce tega preizkusa \u0161e nisi delal, ga naredi zdaj in zapi\u0161i \u0161tevilko. To je tvoja osnova. Ponavljaj vsak mesec. Ko upadanje prese\u017ee 0,15 psi\/min, ima\u0161 2\u20134 tedne, preden postane te\u017eava.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Milna raztopina<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Zme\u0161aj 1 del sredstva za pomivanje posode s 3 deli vode. Napolni komoro na delovni tlak. Popr\u0161i vsako tesnilo, ventil, priklju\u010dek in \u0161iv. Mehur\u010dki = pu\u0161\u010danje.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Varnostna opomba<\/strong>: Razred\u010dene raztopine so po standardih za preizku\u0161anje medicinskih pripomo\u010dkov sprejemljive za opremo v stiku s kisikom, ampak po preizkusu jih takoj obri\u0161i. Nikoli ne uporabljaj detektorjev pu\u0161\u010danja na osnovi nafte.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"500\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Small-bubbles-indicating-an-air-fitting-leak.webp\" alt=\"Majhni mehur\u010dki, ki ka\u017eejo na pu\u0161\u010danje zra\u010dnega priklju\u010dka\" class=\"wp-image-11643\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/Small-bubbles-indicating-an-air-fitting-leak.webp 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Small-bubbles-indicating-an-air-fitting-leak-300x188.webp 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Small-bubbles-indicating-an-air-fitting-leak-768x480.webp 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/Small-bubbles-indicating-an-air-fitting-leak-18x12.webp 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3. Osnovni \u010das polnjenja s tlakom<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Izmeri, koliko \u010dasa traja, da iz okoli\u0161kega tlaka dose\u017ee\u0161 delovni tlak. Delaj to vsak mesec. Zapisuj si.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ko ta \u0161tevilka zleze z 12 minut na 15, pa na 18, ima\u0161 nekje pu\u0161\u010danje. \u010cas delovanja kompresorja ne la\u017ee.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Zakaj NE helij, ultrazvok ali akusti\u010dna emisija?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Iskanje pu\u0161\u010danj s helijem<\/strong>: Ob\u010dutljivost do 10\u207b\u00b9\u00b2 mbar\u00b7l\/s. Odli\u010dno za vakumske komore. Preve\u010d za mehko hiperbari\u010dno komoro, kjer lovi\u0161 upadanje 0,5 psi\/min. Oprema stane 8.000\u201325.000 $.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ultrazvo\u010dno iskanje<\/strong>: Deluje pri stisnjenem zraku 80\u2013120 psi. Tvoja komora dela pri 7\u201322 psi. Zna\u010dilnost pu\u0161\u010danja je pod mejo uporabne ob\u010dutljivosti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Akusti\u010dna emisija<\/strong>:&nbsp;<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/39288925\/\" target=\"_blank\" rel=\"noopener\">\u0161tudija iz leta 2024<\/a>&nbsp;dokumentira AE za ponovno potrditev ve\u010dmestnih komor Class B (odkrivanje napetostno-korozijskih razpok v jeklenih ohi\u0161jih). \u010ce uporablja\u0161 mehko komoro za wellness, to ni tvoja raba.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Matrika diagnosti\u010dnih odlo\u010ditev<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Simptom<\/th><th>Verjetni vzrok<\/th><th>Kako izklju\u010diti<\/th><th>Dejanje<\/th><\/tr><\/thead><tbody><tr><td>Po\u010dasno polnjenje + sli\u0161en \u0161um pri vratih<\/td><td>Dotrajano tesnilo vrat<\/td><td>Preizkus z milom pri vratih pod tlakom<\/td><td>Zamenjaj tesnilo; preglej za onesna\u017eenje<\/td><\/tr><tr><td>Po\u010dasno polnjenje + ni sli\u0161nega pu\u0161\u010danja<\/td><td>Notranje pu\u0161\u010danje ventila ali priklju\u010dka<\/td><td>Preizkus priklju\u010dkov z milom; preveri PRV<\/td><td>Obnovi ventil; zamenjaj O-obro\u010de<\/td><\/tr><tr><td>Dose\u017ee tlak in nato po\u010dasi pade (kompresor izklopljen)<\/td><td>Razgradnja tesnila ali mikrorazpoka v akrilu<\/td><td>Preizkus zadr\u017eevanja tlaka + milni preizkus oken in \u0161ivov<\/td><td>Zamenjaj tesnilo; preglej okno s pove\u010devalnim steklom<\/td><\/tr><tr><td>Kompresor te\u010de neprekinjeno, tlak se ne ustali<\/td><td>PRV zataknjen odprt ali ve\u010dja po\u0161kodba konstrukcije<\/td><td>Ro\u010dno preveri PRV; preglej zatrganine tkanine<\/td><td>Zamenjaj PRV; \u010de je tkanina zatrgana, takoj umakni iz uporabe<\/td><\/tr><tr><td>\u010cas polnjenja se iz meseca v mesec podalj\u0161uje<\/td><td>Obraba tesnila ali neporavnan okvir<\/td><td>Primerjaj osnovo s trenutnim stanjem; preveri vodoravnost okvirja<\/td><td>Na\u010drtovana zamenjava tesnila; ponovno poravnaj okvir<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Postopek preizkusa zadr\u017eevanja tlaka<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pripravi komoro<\/strong>: Odstrani osebe, blazine in predmete, ki niso pritrjeni. Popolnoma zapri vrata\/zadrgo.<\/li>\n\n\n\n<li><strong>Napolni na delovni tlak<\/strong>: 1,5 ATA = 7,3 psig; 1,3 ATA = 4,4 psig.<\/li>\n\n\n\n<li><strong>Izoliraj<\/strong>: Izklopi kompresor, zapri izolacijski ventil. Komora je zdaj zaprt sistem.<\/li>\n\n\n\n<li><strong>Za\u010dni meriti \u010das<\/strong>: Zapi\u0161i to\u010den tlak. Uporabi umerjen merilnik z natan\u010dnostjo \u00b10,1 psi.<\/li>\n\n\n\n<li><strong>Po\u010dakaj 10\u201315 minut<\/strong>: Ne odpiraj vrat. Ne dotikaj se krmiljenja.<\/li>\n\n\n\n<li><strong>Zabele\u017ei kon\u010dni tlak<\/strong>: Izra\u010dunaj hitrost upadanja = (za\u010detni psi \u2212 kon\u010dni psi) \u00f7 pretekle minute.<\/li>\n\n\n\n<li><strong>Primerjaj z mejo<\/strong>: &lt;0,1 = uspe\u0161no, 0,1\u20130,3 = pod nadzorom, &gt;0,3 = neuspe\u0161no.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Opomba o umerjanju<\/strong>: Tla\u010dne merilne celice v medicinski opremi je treba enkrat letno preveriti glede na referenco, za katero ve\u0161, da je dobra. Napa\u010dno umerjen merilnik stane ve\u010d zaradi napa\u010dnih ugotovitev kot samo umerjanje.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kaj zamenjati in kdaj<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tesnila vrat (mehke komore)<\/strong>: Vsakih 1.000\u20131.500 obratovalnih ur. Pri 1.500 urah letno (6 seans\/dan \u00d7 5 dni\/teden) to pomeni letno zamenjavo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>O-obro\u010di ventilov<\/strong>: Vsakih 2.000 ur ali ob odkritem pu\u0161\u010danju, kar pride prej.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tesnila oken<\/strong>: Vsakih 2.500 ur ali ob vidnih razpokah.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stro\u0161ki (samo deli, OEM):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tesnilo vrat: 120\u2013180 $<\/li>\n\n\n\n<li>Komplet za obnovo ventila: 45\u201380 $<\/li>\n\n\n\n<li>Sklop akrilnega okna: 850\u20131.200 $<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Sam ali mojster<\/strong>: Zamenjava tesnila vrat je preprosta \u2014 izvle\u010de\u0161 staro tesnilo iz utora, o\u010disti\u0161 z izopropilnim alkoholom, vtisne\u0161 novo. Brez posebnega orodja. Obnova ventilov zahteva razstavljanje in predpisane zatezne momente. Zamenjava akrilnega okna vklju\u010duje konstrukcijske vijake in celovitost tla\u010dne meje \u2014<strong>tega ne delaj sam<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Skladnost s predpisi<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Kaj standardi v resnici pravijo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/safety-standard-for-pressure-vessels-for-human-occupancy\" target=\"_blank\" rel=\"noopener\">ASME PVHO-2<\/a>&nbsp;je standard za tla\u010dne posode za ljudi v obratovanju. Podaja metodologijo preizku\u0161anja (zadr\u017eevanje tlaka, preverjanje naprave za spro\u0161\u010danje tlaka), ki velja tudi za prenosne mehke komore pod uradnim pragom razvrstitve med tla\u010dne posode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/uhms.org\/images\/Accreditation-Documents\/Fourth_Edition_UHMS_Accreditation_Manual_Final.pdf\" target=\"_blank\" rel=\"noopener\">Priro\u010dnik UHMS za akreditacijo klini\u010dnih hiperbari\u010dnih ustanov<\/a>&nbsp;(4. izdaja) vklju\u010duje zahteve za program vzdr\u017eevanja: preizkus zadr\u017eevanja tlaka, preizkus delovanja PRV (ro\u010dni dvig, preverjanje izpusta), zamenjava vlo\u017eka sesalnega filtra kompresorja, umerjanje analizatorja kisika, preizkus neprekinjenosti ozemljitve, pregled celovitosti tesnil, dokumentiranje osnovnega \u010dasa polnjenja s tlakom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.fda.gov\/medical-devices\/letters-health-care-providers\/follow-instructions-safe-use-hyperbaric-oxygen-therapy-devices-letter-health-care-providers\" target=\"_blank\" rel=\"noopener\">Dopis FDA iz leta 2025 ponudnikom zdravstvenih storitev<\/a>&nbsp;poudarja, da je treba upo\u0161tevati intervale vzdr\u017eevanja in varnostne preglede, ki jih priporo\u010da proizvajalec, za vsako napravo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.osha.gov\/pressure-vessels\" target=\"_blank\" rel=\"noopener\">Navodila OSHA o tla\u010dnih posodah<\/a>&nbsp;zajemajo sisteme stisnjenega zraka. \u010ce sistem kompresorja tvoje komore vklju\u010duje zalogovnik zraka, je treba enkrat letno opraviti zunanji pregled, vsako posodo pa je treba po popravilu pred vrnitvijo v uporabo preizkusiti na pu\u0161\u010danje.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Izdelki na osnovi nafte v okolju s kisikom<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Izdelki na osnovi nafte so v okolju, obogatenem s kisikom, prepovedani. To ni samovoljno \u2014 materiali, ki vsebujejo vazelin, mineralno olje ali parafin, imajo v pogojih \u010distega kisika toploto izgorevanja primerljivo z bencinom. Obstajajo alternative na vodni ali silikonski osnovi, ki so varne za komoro.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zato za iskanje pu\u0161\u010danj uporablja\u0161 milno raztopino na vodni osnovi, ne WD-40 ali pr\u0161ilnih tesnilnih mas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pogosta vpra\u0161anja<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Koliko letno stane vzdr\u017eevanje hiperbari\u010dne komore?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Za eno mehko komoro v komercialni rabi (6 seans\/dan, 5 dni\/teden):<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Na\u010drtovano vzdr\u017eevanje: 600\u20131.200 $ (letni pregled + preventivno vzdr\u017eevanje)<\/li>\n\n\n\n<li>Zamenjava tesnila: 300\u2013500 $ (deli + delo, eno tesnilo vrat)<\/li>\n\n\n\n<li>Filter\/olje kompresorja: 150\u2013300 $<\/li>\n\n\n\n<li>Umerjanje analizatorja kisika: 100\u2013200 $<\/li>\n\n\n\n<li><strong>Skupaj: 2.200\/leto<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u010ce pu\u0161\u010danja ujame\u0161 zgodaj z mese\u010dnimi preizkusi zadr\u017eevanja tlaka, ostane\u0161 v tem okviru. \u010ce jih ignorira\u0161, pri\u0161tej \u0161e 1.500\u20133.000 $ za interventne klice in izgubljeni prihodek.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kako pogosto je treba zamenjati tesnila vrat?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vsakih 1.000\u20131.500 obratovalnih ur<\/strong>, ali prej, \u010de preizkus zadr\u017eevanja tlaka poka\u017ee upadanje &gt;0,15 psi\/min. Pri 1.500 urah letno to pomeni&nbsp;<strong>letno zamenjavo<\/strong>. Objekti z veliko uporabo (2.500+ ur letno) naj na\u010drtujejo&nbsp;<strong>vsakih 8\u201310 mesecev<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ali lahko v okolju s kisikom uporabi\u0161 milnico?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Da, a previdno. Uporabi razred\u010deno raztopino (1:3 milo:voda), nanesi jo od zunaj na sumljiva mesta in&nbsp;<strong>takoj obri\u0161i<\/strong>. Vodni tenzidi so za opremo v stiku s kisikom sprejemljivi, \u010de ne pridejo v neposreden stik z dovodnimi cevmi kisika in se po preizkusu odstranijo. Ne pr\u0161i v notranjost komore ali na dele za dovajanje kisika.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kaj je 10\u201315 minutni preizkus zadr\u017eevanja tlaka?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Napolni prazno komoro na delovni tlak, izklopi kompresor, zapri izolacijski ventil in opazuj merilnik tlaka 10\u201315 minut. Sprejemljivo upadanje je&nbsp;<strong>&lt;0,1 psi\/min<\/strong>&nbsp;pri tesnjenih komorah. Upadanje &gt;0,3 psi\/min pomeni aktivno pu\u0161\u010danje, ki ga je treba takoj popraviti. Zapisuj vsak mesec, da vzpostavi\u0161 osnovo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kdaj nehati iskati napako in poklicati strokovnjaka?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PRV je zataknjen odprt ali se ne usede nazaj<\/li>\n\n\n\n<li>Na\u0161el si razpoko v oknu ali zatrganino v konstrukcijski tkanini<\/li>\n\n\n\n<li>Komora ob delujo\u010dem kompresorju ne dose\u017ee 50 % nazivnega tlaka<\/li>\n\n\n\n<li>Gre za elektri\u010dne komponente ali napeljavo senzorjev<\/li>\n\n\n\n<li>Zamenjal si tesnilo vrat, pu\u0161\u010danje pa ostaja (verjetno notranje)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ne loti se obnove ventilov brez predpisanih zateznih momentov ali zamenjave okna brez ustrezne tesnilne mase \u2014 oboje lahko naredi ve\u010djo \u0161kodo.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ali lahko pu\u0161\u010danje naredi seanso neu\u010dinkovito, tudi \u010de tlak na koncu dose\u017ee\u0161?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Da. \u010ce polnjenje traja 25 minut namesto 12, stranka pre\u017eivi 20+ minut pod premajhnim tlakom. Od 60-minutne seanse, ki je bila na\u010drtovana, morda dobi le 40\u201345 minut \u010dasa pri polnem tlaku. Merilnik morda ka\u017ee 1,5 ATA, ampak \u010de je do tja trajalo predolgo, je u\u010dinek seanse manj\u0161i.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zato je osnovni \u010das polnjenja s tlakom klju\u010dna diagnosti\u010dna meritev.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Kon\u010dna beseda<\/strong>: S komoro z majhnim pu\u0161\u010danjem lahko dela\u0161 mesece. Napolnila se bo. Merilnik bo kazal v redu, ko dose\u017ee\u0161 tlak. Ampak vsaka seansa traja malo dlje, po\u017ere malo ve\u010d kisika, kompresor malo bolj obremeni. \u010cez \u0161est mesecev so obratovalni stro\u0161ki vi\u0161ji za 18 %, stranke pa spra\u0161ujejo, zakaj se seanse vle\u010dejo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ali pa ta teden porabi\u0161 15 minut z merilnikom in pr\u0161ilko.<\/p>","protected":false},"excerpt":{"rendered":"<p>We make hyperbaric chambers. And here&#8217;s something we tell every customer when they call about slow pressurization:\u00a0your chamber will leak. Not &#8220;if,&#8221; but &#8220;when.&#8221; Door seals wear, valve seats erode, acrylic windows develop microfractures. The question isn&#8217;t whether it&#8217;ll happen\u2014it&#8217;s whether you&#8217;ll catch it before it burns through session time, oxygen, and treatment capacity. This [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":11641,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-11640","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/11640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/comments?post=11640"}],"version-history":[{"count":1,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/11640\/revisions"}],"predecessor-version":[{"id":11644,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/11640\/revisions\/11644"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/media\/11641"}],"wp:attachment":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/media?parent=11640"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/categories?post=11640"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/tags?post=11640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}