{"id":7018,"date":"2026-05-18T15:34:16","date_gmt":"2026-05-18T07:34:16","guid":{"rendered":"https:\/\/oxy-boss.com\/?p=7018"},"modified":"2026-07-07T12:00:05","modified_gmt":"2026-07-07T04:00:05","slug":"razumevanje-ata-v-hiperbaricnih-komorah","status":"publish","type":"post","link":"https:\/\/oxy-boss.com\/sl\/understanding-ata-in-hyperbaric-chambers\/","title":{"rendered":"Kaj pomeni ATA pri hiperbari\u010dni komori in zakaj je vrednost na merilniku pomembna"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-9645\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-hyperbaric-chamber-cover.jpg\" alt=\"ATA hyperbaric chamber cover\" width=\"800\" height=\"500\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-hyperbaric-chamber-cover.jpg 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-hyperbaric-chamber-cover-300x188.jpg 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-hyperbaric-chamber-cover-768x480.jpg 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-hyperbaric-chamber-cover-600x375.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Morda gledate manometer z oznako \u00bb1,5 ATA\u00ab ali primerjate tehni\u010dne liste, kjer je pri enem modelu navedeno 1,3, pri drugem pa 2,0. Klju\u010dno vpra\u0161anje ni le, kaj pomeni ATA, temve\u010d tudi, kako ta vrednost vpliva na tlak v komori, parcialni tlak kisika, udobje uporabnika, zahteve glede opreme in namestitev.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Za <a href=\"https:\/\/oxy-boss.com\/sl\/\">nemedicinske hiperbari\u010dne komore<\/a>, je ATA ena najpomembnej\u0161ih specifikacij. Vpliva na zasnovo in delovanje komore ter na uporabni\u0161ko izku\u0161njo.<\/span><\/p>\n<h2><b>ATA: kratka definicija<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">ATA pomeni <\/span><b>Absolutne atmosfere<\/b><span style=\"font-weight: 400;\">. Meri <\/span><b>skupni tlak<\/b><span style=\"font-weight: 400;\"> ki deluje na vas \u2013 tlak ozra\u010dja, v katerem se \u017ee nahajate, skupaj z dodatnim tlakom, ki ga ustvari komora.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Na morski gladini ali blizu nje je obi\u010dajni atmosferski tlak <\/span><b>1.0 ATA<\/b><span style=\"font-weight: 400;\">. To je <\/span><b>14.7 PSI<\/b><span style=\"font-weight: 400;\"> ali <\/span><b>101.3 kPa<\/b><span style=\"font-weight: 400;\">. Druga\u010dne enote, ista fizi\u010dna resni\u010dnost.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Ko je komora pod tlakom <\/span><b>1.5 ATA<\/b><span style=\"font-weight: 400;\">, deluje s 50 % ve\u010djim skupnim tlakom od obi\u010dajnega atmosferskega tlaka. Pri <\/span><b>2.0 ATA<\/b><span style=\"font-weight: 400;\">se skupni tlak podvoji.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Zakaj \u201eabsolutno\u201c? Ker \u0161tevilni industrijski merilniki prikazujejo <\/span><b>nadtlak<\/b><span style=\"font-weight: 400;\">, kar pomeni tlak nad atmosferskim tlakom. Od\u010ditek 0 PSI na manometru pomeni obi\u010dajni tlak okolice, ne vakuuma. ATA odpravi to dvoumnost. Komora, nastavljena na <\/span><b>1.5 ATA<\/b><span style=\"font-weight: 400;\"> predstavlja enak notranji absolutni tlak ne glede na lokalno nadmorsko vi\u0161ino, \u010deprav se lahko od\u010ditek v PSI na manometru razlikuje glede na lokacijo.<\/span><\/p>\n<p><b>Informativna opomba:<\/b><span style=\"font-weight: 400;\"> Ta \u010dlanek ponuja splo\u0161ne informacije o izrazoslovju tlaka in izbiri opreme za <\/span><b>nemedicinske hiperbari\u010dne komore<\/b><span style=\"font-weight: 400;\">. Ne gre za zdravstveni nasvet in ne trdi, da diagnosticira, zdravi, ozdravi ali prepre\u010duje katero koli bolezen. Uporabniki morajo upo\u0161tevati navodila proizvajalca in veljavne lokalne zahteve ter se za osebna zdravstvena vpra\u0161anja posvetovati z usposobljenim strokovnjakom.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-9644\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-pressure-tabletop-concept.jpg\" alt=\"ATA pressure tabletop concept\" width=\"800\" height=\"500\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-pressure-tabletop-concept.jpg 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-pressure-tabletop-concept-300x188.jpg 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-pressure-tabletop-concept-768x480.jpg 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/ATA-pressure-tabletop-concept-600x375.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2><b>Fizika plinov za \u0161tevilko<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Dva plinska zakona pojasnjujeta ve\u010dino tega, kar je tukaj pomembno: <\/span><b>Henryjev zakon<\/b><span style=\"font-weight: 400;\"> in <\/span><b>Boyleov zakon<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<h3><b>Henryjev zakon<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Koli\u010dina plina, ki se raztopi v teko\u010dini, je neposredno sorazmerna z delnim tlakom tega plina nad teko\u010dino.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">V komori zvi\u0161anje tlaka spremeni parcialni tlak kisika in lahko pove\u010da koli\u010dino kisika, ki se fizi\u010dno raztopi v plazmi. Obseg spremembe je v praksi odvisen od <\/span><b>dve spremenljivki<\/b><span style=\"font-weight: 400;\">: skupni tlak v komori in vdihani dele\u017e kisika.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">To opisuje parcialni tlak kisika (<\/span><b>ppO\u2082<\/b><span style=\"font-weight: 400;\">):<\/span><\/p>\n<p><b>ppO\u2082 = FiO\u2082 \u00d7 P(ATA)<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Kjer:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>FiO\u2082<\/b><span style=\"font-weight: 400;\"> = dele\u017e vdihanega kisika<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>P(ATA)<\/b><span style=\"font-weight: 400;\"> = skupni tlak v komori<\/span><\/li>\n<\/ul>\n<h3><b>Primeri parcialnega tlaka kisika<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Pogoj dihanja<\/b><\/td>\n<td><b>FiO\u2082<\/b><\/td>\n<td><b>Tlak (ATA)<\/b><\/td>\n<td><b>Nastali ppO\u2082 (ATA)<\/b><\/td>\n<td><b>Pribli\u017eni ekvivalent na morski gladini<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Sobni zrak na morski gladini<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.21<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.21<\/span><\/td>\n<td><span style=\"font-weight: 400;\">21 % izhodi\u0161\u010de<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Maska z 93 % O\u2082 na morski gladini<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.93<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.93<\/span><\/td>\n<td><span style=\"font-weight: 400;\">93%<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Sobni zrak pri 1.5 ATA (brez maske)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.21<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.32<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~32 % ekvivalent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Me\u0161anica s 60 % O\u2082 pri 1.5 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.60<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.90<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~90 % ekvivalent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Maska z 93 % O\u2082 pri 1.5 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.93<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.40<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~140 % ekvivalent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">100 % O\u2082 pri 2.0 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.00<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.00<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~200 % ekvivalent<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Prakti\u010dni sklep je preprost: <\/span><b>tlak pomno\u017ei parcialni tlak kisika<\/b><span style=\"font-weight: 400;\">. Ne doda le koncentracije kisika.<\/span><\/p>\n<h3><b>Boyleov zakon<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Pri stalni temperaturi sta prostornina in tlak obratno sorazmerna. \u010ce se tlak pove\u010da, se prostornina plina zmanj\u0161a.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">V komori je to pomembno iz dveh glavnih razlogov:<\/span><\/p>\n<p><b>Izena\u010devanje u\u0161es.<\/b><span style=\"font-weight: 400;\"> Z nara\u0161\u010danjem tlaka se zra\u010dni prostor v srednjem u\u0161esu stisne. Uporabniki tlak obi\u010dajno izena\u010dijo s po\u017eiranjem, zehanjem ali premikanjem \u010deljusti, podobno kot pri spu\u0161\u010danju letala ali potapljanju.<\/span><\/p>\n<p><b>Gostota plina.<\/b><span style=\"font-weight: 400;\"> Pri vi\u0161jem ATA vsak vdih vsebuje ve\u010d molekul plina v enaki prostornini. Kompresor in sistem pretoka zraka morata biti zato ustrezno dimenzionirana, da zagotovita izmenjavo sve\u017eega zraka pri ciljnem tlaku.<\/span><\/p>\n<h2><b>Tla\u010dne stopnje \u2013 kaj vsak obseg ATA obi\u010dajno pomeni<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Vsak razpon ATA vklju\u010duje druga\u010dno opremo, zahteve glede delovanja in premisleke glede prostora.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Obseg ATA<\/b><\/td>\n<td><b>Ekvivalentna globina vode<\/b><\/td>\n<td><b>Obi\u010dajen tip komore<\/b><\/td>\n<td><b>Obi\u010dajno trajanje seje*<\/b><\/td>\n<td><b>Obi\u010dajna poraba mo\u010di sistema<\/b><\/td>\n<td><b>Raven hrupa (obi\u010dajna)<\/b><\/td>\n<td><b>Tipi\u010den kontekst uporabe<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.0 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Povr\u0161ina<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Se ne uporablja<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Se ne uporablja<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Se ne uporablja<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Se ne uporablja<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Obi\u010dajni okoljski tlak<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.3 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~10 ft \/ 3 m<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Mehko ohi\u0161je (TPU\/PET)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">60\u201390 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">200\u2013520 W<\/span><\/td>\n<td><span style=\"font-weight: 400;\">45\u201355 dB<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Osnovna doma\u010da uporaba<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.5 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~16 ft \/ 5 m<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Oja\u010dano mehko ohi\u0161je<\/span><\/td>\n<td><span style=\"font-weight: 400;\">60\u201390 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">520\u2013800 W<\/span><\/td>\n<td><span style=\"font-weight: 400;\">50\u201360 dB<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Uporaba mehkega ohi\u0161ja pri vi\u0161jem tlaku<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2.0 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~33 ft \/ 10 m<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Trdo ohi\u0161je (jeklo\/aluminij)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">45\u201360 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.5\u20134.0 kW<\/span><\/td>\n<td><span style=\"font-weight: 400;\">55\u201365 dB (z du\u0161enjem)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Komercialne instalacije s trdim ohi\u0161jem ali v namenski sobi<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2.4 ATA<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~46 ft \/ 14 m<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Trdo ohi\u0161je (jeklo\/aluminij, izvedba za ve\u010dje obremenitve)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">40\u201350 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.5\u20135.0+ kW<\/span><\/td>\n<td><span style=\"font-weight: 400;\">60\u201372 dB<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Specializirane instalacije z vi\u0161jim tlakom<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">*Dejansko trajanje seje je odvisno od navodil proizvajalca, protokola delovanja in okoli\u0161\u010din uporabnika.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Nekaj stvari je vrednih pozornosti:<\/span><\/p>\n<p><b>\u010casi sej se pogosto skraj\u0161ajo z nara\u0161\u010danjem ATA.<\/b><span style=\"font-weight: 400;\"> Sistemi z vi\u0161jim tlakom so obi\u010dajno povezani s kraj\u0161imi proizvajal\u010devimi protokoli delovanja.<\/span><\/p>\n<p><b>Poraba mo\u010di se nad 1.5 ATA hitro pove\u010da.<\/b><span style=\"font-weight: 400;\"> Mehka enota lahko porabi manj energije kot \u0161tevilni gospodinjski aparati, medtem ko lahko togi sistem z 2,0 ATA zahteva ve\u010d kilovatov, \u010de upo\u0161tevamo kompresor, vir kisika, hlajenje in krmiljenje.<\/span><\/p>\n<p><b>Hrup postane resni\u010den dejavnik pri namestitvi.<\/b><span style=\"font-weight: 400;\"> Sistemi z vi\u0161jim tlakom obi\u010dajno potrebujejo ve\u010dje kompresorje, zato je pogosto treba bolje na\u010drtovati obvladovanje hrupa.<\/span><\/p>\n<h2><b>Tabela enot \u2013 ATA proti PSI proti bar proti kPa<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Tukaj je osnovna pretvorbena tabela:<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>ATA<\/b><\/td>\n<td><b>Manometrski PSI (nad atmosferskim)<\/b><\/td>\n<td><b>Bar (absolutno)<\/b><\/td>\n<td><b>kPa (absolutno)<\/b><\/td>\n<td><b>Ekvivalentna globina (morska voda)<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.01<\/span><\/td>\n<td><span style=\"font-weight: 400;\">101.3<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Povr\u0161ina<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.3<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~4.4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.32<\/span><\/td>\n<td><span style=\"font-weight: 400;\">131.7<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~10 ft \/ 3 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1.5<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~7.4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.52<\/span><\/td>\n<td><span style=\"font-weight: 400;\">151.9<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~16.5 ft \/ 5 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~14.7<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.03<\/span><\/td>\n<td><span style=\"font-weight: 400;\">202.6<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~33 ft \/ 10 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2.4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~20.6<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.43<\/span><\/td>\n<td><span style=\"font-weight: 400;\">243.2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~46 ft \/ 14 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">3.0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~29.4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3.04<\/span><\/td>\n<td><span style=\"font-weight: 400;\">303.9<\/span><\/td>\n<td><span style=\"font-weight: 400;\">~66 ft \/ 20 m<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Hitra pretvorba:<\/span><\/p>\n<p><b>1 ATA = 14.7 PSI = 1.013 bar = 101.3 kPa<\/b><\/p>\n<p><span style=\"font-weight: 400;\">\u010ce v podatkovnem listu pi\u0161e <\/span><b>\u201edelovni tlak: 4.4 PSI\u201c,<\/b><span style=\"font-weight: 400;\"> gre obi\u010dajno za <\/span><b>nadtlak<\/b><span style=\"font-weight: 400;\">. Dodajte atmosferski tlak, da ga pretvorite v absolutni tlak \u2013 ta zna\u0161a pribli\u017eno <\/span><b>1.3 ATA<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<h2><b>Zakaj \u201evi\u0161ji ATA\u201c ni samodejno \u201ebolje\u201c<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">To je ena najpomembnej\u0161ih prakti\u010dnih to\u010dk.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Vi\u0161ji ATA ne pomeni le \u00bbve\u010d istega\u00ab. Z nara\u0161\u010danjem tlaka se hkrati spremeni ve\u010d dejavnikov:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">zahteve po udobju in izena\u010devanju u\u0161es<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">zahteve glede konstrukcije komore<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">velikost kompresorja in potrebe po zra\u010dnem toku<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">hrup in poraba energije<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">zahtevnost vzdr\u017eevanja<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">zahteve glede lokacije in namestitve<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Ustrezen ATA ni samodejno najvi\u0161ji. Ustreza predvideni nemedicinski uporabi, razpolo\u017eljivemu prostoru, prora\u010dunu za delovanje in zahtevam glede udobja.<\/span><\/p>\n<h2><b>Mehko ohi\u0161je proti trdemu \u2013 meja ATA<\/b><\/h2>\n<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/oxy-boss.com\/sl\/mehka-prenosna-hiperbaricna-komora\/\">Mehke komore<\/a> so obi\u010dajno izdelane iz ve\u010dplastnega poliestra TPU\/PET z varjenimi \u0161ivi in oja\u010danimi zapirali. Obi\u010dajno delujejo v obmo\u010dju <\/span><b>1.3 do 1.5 ATA<\/b><span style=\"font-weight: 400;\"> obi\u010dajnega obmo\u010dja, nekateri modeli pa segajo nekoliko vi\u0161je. Pri teh sistemih je tla\u010dna posoda kar tekstilna lupina.<\/span><\/p>\n<h3><b>Klju\u010dni tehni\u010dni parametri za kamere z mehkim ohi\u0161jem<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Tip kompresorja:<\/b><span style=\"font-weight: 400;\"> brezoljni nihajni bat ali membrana<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Zra\u010dni tok pod tlakom:<\/b><span style=\"font-weight: 400;\"> obi\u010dajno 100\u2013130+ LPM pri ciljnem ATA<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Delovni cikel:<\/b><span style=\"font-weight: 400;\"> pogosto 80\u2013100 %<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u010cas povi\u0161anja tlaka:<\/b><span style=\"font-weight: 400;\"> pribli\u017eno 8\u201315 minut<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Postavitev:<\/b><span style=\"font-weight: 400;\"> pogosto izvedljivo v stanovanjskih prostorih<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Te\u017ea:<\/b><span style=\"font-weight: 400;\"> pribli\u017eno 25\u201380 kg, odvisno od modela<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Vzdr\u017eevanje:<\/b><span style=\"font-weight: 400;\"> redne menjave filtrov, pregledi tesnil in ob\u010dasno testiranje tesnosti<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/oxy-boss.com\/sl\/hiperbaricna-komora-s-trdo-lupino\/\">Komore s togo lupino<\/a> uporabljajo togo tla\u010dno posodo iz jekla ali aluminija, obi\u010dajno z akrilnimi vrati ali oknom za opazovanje ter bolj integriranim sistemom kompresorja, kisika in hlajenja. Ti sistemi obi\u010dajno delujejo od <\/span><b>1.5 ATA navzgor<\/b><span style=\"font-weight: 400;\">, vklju\u010dno z <\/span><b>2.0 ATA in ve\u010d<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<h3><b>Klju\u010dni tehni\u010dni parametri za kamere s trdim ohi\u0161jem<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Kompresor:<\/b><span style=\"font-weight: 400;\"> industrijski brezoljni sistemi, pogosto 4+ KM<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Zra\u010dno hlajenje:<\/b><span style=\"font-weight: 400;\"> obi\u010dajno potrebno nad 1.5 ATA za obvladovanje toplote stiskanja<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Upravljanje CO\u2082:<\/b><span style=\"font-weight: 400;\"> namensko \u010di\u0161\u010denje ali vi\u0161je stopnje prezra\u010devanja<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Zasilno zni\u017eanje tlaka:<\/b><span style=\"font-weight: 400;\"> zasnovano v skladu z veljavnimi standardi za opremo in varnost<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Upravljanje:<\/b><span style=\"font-weight: 400;\"> programirljivi tla\u010dni profili, samodejne rampe in varnostne zapore<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Vzdr\u017eevanje:<\/b><span style=\"font-weight: 400;\"> na\u010drtovani strokovni pregled, zamenjava tesnil, pregled okenca in servisiranje kompresorja<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Temeljna konstrukcijska to\u010dka je preprosta: <\/span><b>tkanina se pod tlakom razteza; togi vsebniki se ne.<\/b><span style=\"font-weight: 400;\"> Z nara\u0161\u010danjem delovnega tlaka postane toga konstrukcija prakti\u010dna oblikovalska re\u0161itev.<\/span><\/p>\n<h2><b>Kaj se zgodi med sejo \u2013 osnovni potek<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Obi\u010dajna seja v komori poteka v \u0161tirih korakih:<\/span><\/p>\n<ol>\n<li><b> Tesnjenje in predhodni pregled.<\/b><span style=\"font-weight: 400;\"> Komoro zaprete in opravite osnovne preglede delovanja. Pri naprednej\u0161ih sistemih lahko ti vklju\u010dujejo stanje tesnil, pripravljenost kompresorja in vira kisika, prezra\u010devanje ter notranjo temperaturo.<\/span><\/li>\n<li><b> Faza stiskanja (5\u201315 min).<\/b><span style=\"font-weight: 400;\"> Tlak v komori se nadzorovano zvi\u0161a do ciljne vrednosti. Uporabniki lahko ob\u010dutijo rahlo polnost v u\u0161esih, ki jo obi\u010dajno izena\u010dijo s po\u017eiranjem ali ne\u017enim premikanjem \u010deljusti.<\/span><\/li>\n<li><b> Faza zadr\u017eevanja (40\u201390 min, odvisno od sistema).<\/b><span style=\"font-weight: 400;\"> Ko je dose\u017een ciljni ATA, tlak ostane stabilen. \u010ce se uporablja dodatni kisik, se v tej fazi skupaj vzdr\u017eujeta izbrani tlak in dele\u017e kisika. Prezra\u010devanje in uravnavanje temperature se nadaljujeta skozi celotno sejo.<\/span><\/li>\n<li><b> Faza spro\u0161\u010danja tlaka (5\u201315 min).<\/b><span style=\"font-weight: 400;\"> Tlak se postopoma vrne na raven okolice. Med vra\u010danjem komore na obi\u010dajni atmosferski tlak lahko uporabniki ob\u010dutijo rahlo spremembo tlaka v u\u0161esih.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Z vidika udobja se ob\u010dutek pogosto primerja s po\u010dasnim in nadzorovanim spu\u0161\u010danjem letala.<\/span><\/p>\n<h2><b>Izbira ATA: prakti\u010den okvir za odlo\u010danje<\/b><\/h2>\n<h3><b>Za osebno doma\u010do uporabo<\/b><\/h3>\n<p><b>1.3 ATA<\/b><span style=\"font-weight: 400;\"> Pogosta za\u010detna izbira: prenosna, razmeroma tiha in enostavna za postavitev v obi\u010dajni sobi. Pogosto se izbere, kadar so pomembni preprostost, manj\u0161a poraba energije in doma\u010da uporaba.<\/span><\/p>\n<p><b>1.5 ATA<\/b><span style=\"font-weight: 400;\"> Vmesna mo\u017enost za uporabnike, ki \u017eelijo vi\u0161ji tlak, vendar ostati pri mehki komori. Velikost kompresorja, hrup in potrebe po pretoku zraka so obi\u010dajno ve\u010dji kot pri 1,3 ATA.<\/span><\/p>\n<p><b>1.8\u20132.0 ATA<\/b><span style=\"font-weight: 400;\"> To obi\u010dajno spada na podro\u010dje komor s trdo lupino. Sistemi so te\u017eji in glasnej\u0161i ter zahtevajo ve\u010d prostora, elektri\u010dne mo\u010di in na\u010drtovanja namestitve.<\/span><\/p>\n<h3><b>Za komercialno uporabo ali uporabo v ustanovi<\/b><\/h3>\n<p><b>1.5 ATA mehko ohi\u0161je<\/b><span style=\"font-weight: 400;\"> Pogosto je la\u017eje usposobiti osebje, jo namestiti in vzdr\u017eevati kot sisteme s trdo lupino.<\/span><\/p>\n<p><b>2.0 ATA trdo ohi\u0161je<\/b><span style=\"font-weight: 400;\"> Mo\u017enost, ki zahteva ve\u010d infrastrukture; morda je treba oceniti nosilnost tal, \u0161irino vratnih odprtin, elektri\u010dno zmogljivost, hlajenje in obvladovanje hrupa.<\/span><\/p>\n<p><b>Ve\u010dmestno trdo ohi\u0161je<\/b><span style=\"font-weight: 400;\"> Uporablja se, kadar je v namenskem objektu potrebna ve\u010dja zmogljivost, vendar se pove\u010da tudi zahtevnost delovanja.<\/span><\/p>\n<h2><b>Pogoste napa\u010dne predstave<\/b><\/h2>\n<p><b>\u201ePSI in ATA sta razli\u010dni stvari.\u201c<\/b><span style=\"font-weight: 400;\"> Gre za razli\u010dne enote iste fizikalne koli\u010dine: tlaka.<\/span><\/p>\n<p><b>\u201eNajvi\u0161ji ATA je vedno najbolj\u0161a izbira.\u201c<\/b><span style=\"font-weight: 400;\"> Ne nujno. Vi\u0161ji ATA pomeni tudi ve\u010dje zahteve za opremo, ve\u010d prostorskih omejitev in obi\u010dajno zahtevnej\u0161e upravljanje.<\/span><\/p>\n<p><b>\u201eKomora z mehkim ohi\u0161jem in komora s trdim ohi\u0161jem sta v osnovi enaki.\u201c<\/b><span style=\"font-weight: 400;\"> Ne. Razlikujejo se obmo\u010dje tlaka, konstrukcija, pretok zraka, elektri\u010dne zahteve, te\u017ea in potrebe glede namestitve.<\/span><\/p>\n<p><b>\u201eKomora se napolni s \u010distim kisikom.\u201c<\/b><span style=\"font-weight: 400;\"> V \u0161tevilnih nemedicinskih mehkih sistemih se komora napolni s filtriranim zrakom iz okolice. \u010ce se uporablja dodatni kisik, se ta obi\u010dajno dovaja lo\u010deno prek maske ali kanile. Okolje v komori ni enako okolju s 100-odstotnim kisikom.<\/span><\/p>\n<p><b>\u201eVe\u010d nizkotla\u010dnih sej ustreza eni visokotla\u010dni seji.\u201c<\/b><span style=\"font-weight: 400;\"> Izpostavljenosti razli\u010dnim tlakom niso neposredno primerljive. Pomembni so raven tlaka, dele\u017e kisika, trajanje seje in pogoji delovanja.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-9646\" src=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/Higher-ATA-tradeoff-factors.jpg\" alt=\"Higher ATA tradeoff factors\" width=\"800\" height=\"500\" srcset=\"https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/Higher-ATA-tradeoff-factors.jpg 800w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/Higher-ATA-tradeoff-factors-300x188.jpg 300w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/Higher-ATA-tradeoff-factors-768x480.jpg 768w, https:\/\/oxy-boss.com\/wp-content\/uploads\/2026\/05\/Higher-ATA-tradeoff-factors-600x375.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2><b>Pogosta vpra\u0161anja<\/b><\/h2>\n<p><b>Kaj pomeni ATA?<\/b><span style=\"font-weight: 400;\"> Absolutne atmosfere: skupni tlak glede na vakuum, ki vklju\u010duje obi\u010dajni atmosferski tlak in morebitni dodatni tlak v komori.<\/span><\/p>\n<p><b>Kako pretvorim PSI v ATA?<\/b><span style=\"font-weight: 400;\"> Vzemite <\/span><b>manometrske PSI<\/b><span style=\"font-weight: 400;\">, delite z <\/span><b>14.7<\/b><span style=\"font-weight: 400;\">, nato dodajte <\/span><b>1<\/b><span style=\"font-weight: 400;\">Primer: <\/span><b>7.35 PSI gauge = 1.5 ATA<\/b><\/p>\n<p><b>Ali je 1.5 ATA obi\u010dajen delovni tlak?<\/b><span style=\"font-weight: 400;\"> Da. To je obi\u010dajna raven tlaka pri oja\u010danih mehkih sistemih in pogosto predstavlja prakti\u010dno sredino med prenosnimi sistemi z ni\u017ejim tlakom in komorami s trdo lupino.<\/span><\/p>\n<p><b>Kateri ATA dose\u017ee kamera s trdim ohi\u0161jem?<\/b><span style=\"font-weight: 400;\"> To je odvisno od modela. Kamere s trdim ohi\u0161jem se obi\u010dajno za\u010dnejo pri pribli\u017eno <\/span><b>1.5 ATA<\/b><span style=\"font-weight: 400;\"> in segajo do <\/span><b>2.0 ATA<\/b><span style=\"font-weight: 400;\"> ali ve\u010d, odvisno od zasnove in veljavnih standardov.<\/span><\/p>\n<p><b>Ali lahko ob\u010dutim spremembo tlaka?<\/b><span style=\"font-weight: 400;\"> Obi\u010dajno da, rahlo. Pogosto se ob\u010duti podobno kot pritisk v u\u0161esih med spu\u0161\u010danjem letala.<\/span><\/p>\n<p><b>Kak\u0161na je razlika med ATA in bar?<\/b><span style=\"font-weight: 400;\"> Za namene komore je razlika majhna. <\/span><b>1 ATA \u2248 1.013 bar<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><b>Ali nadmorska vi\u0161ina vpliva na ATA v komori?<\/b><span style=\"font-weight: 400;\"> ATA je absolutna meritev, zato nastavljena ciljna vrednost ATA ozna\u010duje absolutni tlak v komori. Lokalna nadmorska vi\u0161ina lahko vpliva na obremenitev kompresorja, ne spremeni pa pomena nastavljene vrednosti ATA.<\/span><\/p>\n<p><b>Kak\u0161na je razlika med milimi hiperbari\u010dnimi komorami in klini\u010dnimi sistemi z vi\u0161jim tlakom?<\/b><span style=\"font-weight: 400;\"> Delujejo pri razli\u010dnih ravneh tlaka, uporabljajo razli\u010dne zasnove komor in so lahko glede na izdelek in jurisdikcijo podvr\u017eeni razli\u010dnim operativnim, regulativnim in varnostnim okvirom.<\/span><\/p>\n<p><b>Kako vem, kateri ATA je pravi za moj prostor?<\/b><span style=\"font-weight: 400;\"> Za\u010dnite z razpolo\u017eljivim prostorom, elektri\u010dno zmogljivostjo, sprejemljivostjo hrupa, \u017eeleno vrsto komore in pri\u010dakovanji glede vzdr\u017eevanja. Vrednost ATA je le eden od dejavnikov pri izbiri.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>You may be reading a pressure gauge that says \u201c1.5 ATA.\u201d Or comparing spec sheets where one model is listed at 1.3 and another at 2.0. The key question is not only what ATA means, but what that number changes about chamber pressure, oxygen partial pressure, user comfort, equipment requirements, and installation needs. For non-medical [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":9645,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/7018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/comments?post=7018"}],"version-history":[{"count":4,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/7018\/revisions"}],"predecessor-version":[{"id":9647,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/posts\/7018\/revisions\/9647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/media\/9645"}],"wp:attachment":[{"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/media?parent=7018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/categories?post=7018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oxy-boss.com\/sl\/wp-json\/wp\/v2\/tags?post=7018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}